<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-25 09-37-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 4/5, 36 dBuV INTER
Pilot RDS Phase Difference
7.2 kHz 2.9 kHz -51 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
20 kHz 24 kHz 6185 0,0647
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
1,2 dBr 2,20 dBr 3,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 9:37, 25.04.2024
RT
"L'INTERVIEW DE 9H20 - ARTUS - LE 7/10 - FRANCE INTER 1ERE RADIO "
AF EON
92.6, 94.6, 94.9, 99.2, 99.9, 100.2 MHz F203, F209, F222, F202
FM Scope Station: 100.20 MHz, signal: 4/5 (36 dBuV) Max at: 24 kHz MIN: 20 kHz % above 75 kHz: 0,0647 Acquired: 2024/04/25 9:36:24 Total samples: 6185 Equivalent time: 0:05:09 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 3,6 dBr MIN: 1,2 dBr AVE: 2,20 dBr % above 10,2 dBr: 0,0 Last value: 1,7 dBr (2024/04/25 9:36:24) Station: 100.20 MHz, signal: 5/5 (36 dBuV) 09:24 09:26 09:28 09:30 09:32 09:34 09:36 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality